主營產品:
必測Venture料位,美國KM稱重,SETRA壓力,GEMS流量開關,GEMS壓力開關,GEMS壓力,NOHKEN料位開關,NOHKEN液位開關,NOHKEN靜電容料位開關,NOHKEN振動料位開關,東和TOWA
產品目錄 PRODUCT
- 伊瑪ema
- 必測Venture
- 美國KM
- 西特SETRA產品
- 日本能研NOHKEN/
- 英國GEMS捷邁
- joslyn clark強士林克...
- 日本東和制電TOWA料位開關
- Alpha阿爾法
- 安德森-耐格anderson-n...
- ZSON仲圣產品
-
Controller senso...
- MEAS精量電子
-
SENEX森納士壓力變送器
- 以色列索利得solidat
- 西門子siemens
-
日本sentec勝鐵克
- 日本橫河YoKogawa
- 日本能研NOHKEN
-
美國斯盧森SOLUTION產品
-
FLEXIM夾管式流量計
- 羅斯蒙特壓力變送器
-
庫存查詢
-
沃克walker
-
美國Kistler-Morse(...
容器組件
簡單介紹:
* Includes non-linearity hysteresis and non-repeatability at a fixed temperature,美國controller 855系列板貼裝壓力傳感器*18-24VDC input required for 1-10VDC output*
詳情介紹:
美國controller 855系列板貼裝壓力傳感器

Specifications
Accuracy*: | <+/-1.0% FSO |
Stability: | +/0.5% FSO/yr |
Thermal Effects: | +/-0.075% FSO/°C |
Overpressure: | 1-10”WC = 100”WC 11-20”WC = 10x rated pressure 21-30”WC = 5x rated pressure Over 30”WC = 45 PSI |
FSO Pressure Range: | 0/0.25”WC up to 0/15PSI (bi-directional ranges available) |
Compensated Range: | 10° to 50°C |
Adjustments: | Offset, 60% of FSO minimum |
Media: | Non-corrosive, non-ionic gases |
Operating Humidity: | 90% RH non-condensing |
Operating Temp: | -25° to 70°C |
Input Supply: | 12-24 VDC |
Supply Current: | <10mA |
Load Resistance: | 2KΩ minimum |
Output Signal: | 1-5VDC, 1-6VDC, 1-10VDC** (call for custom outputs) |
Electrical Connections: | 0.025” square pins on 0.1” centers (5) – Board-Mountable*** |
Pressure Connections: | Barbed fitting for 1/8” ID tubing |
Dimensions: | Approx. 1.50” x 1.35” x 0.9” (3.81cm x 3.43cm x 2.29cm) |
* Includes non-linearity hysteresis and non-repeatability at a fixed temperature
** 18-24VDC input required for 1-10VDC output
*** Direct-to-board solder connection and optional cable available upon request
Package Drawing
How to Order
A typical order number consists of the model number, pressure range, pressure unit, output and mounting connection.
Model | Type | Output Signal | FSO Pressure Range | Calibration Pressure |
---|---|---|---|---|
855 | D = Differential or Gage* | 0…..1 to 5 volts | 0…..0.25”WC to 5”WC | Customer designated exact FSO |
1…..1 to 6 volts | 1…..>5”WC to 13” WC | |||
2…..1 to 10 volts** | 2…..>0.5PSI to 1PSI | |||
5…..Custom Output | 3…..>1PSI to 5PSI | |||
4…..>5PSI to 15PSI |
Example: 855D 5” 12D 0 (Model number 855, differential or gage type unit, pressure range of 0-5” WC, output signal of 1-5 VDC)
* With a gage application, one of the two ports is vented to atmosphere
** Requires 18-24 VDC input
Note: This unit is not designed to support any capacitive load on the output. Please contact Controller Sensors LLC for additional installation guidance